BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Metropolitan Kansas City - ECPv6.15.18//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Metropolitan Kansas City
X-ORIGINAL-URL:https://metrokcicc.org
X-WR-CALDESC:Events for Metropolitan Kansas City
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Chicago
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20240310T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20241103T070000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20250309T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20251102T070000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20260308T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20261101T070000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Chicago:20251210T090000
DTEND;TZID=America/Chicago:20251210T160000
DTSTAMP:20260414T043150
CREATED:20251120T163204Z
LAST-MODIFIED:20251121T174412Z
UID:421-1765357200-1765382400@metrokcicc.org
SUMMARY:Day 1 Training Fire and Smoke Separations + Construction Classification
DESCRIPTION:Day 1 is organized by the Metro Kansas City Chapter of ICC. \nIn-Person or Virtual\nBoth days of training are offered either in person at Lenexa City Hall or virtually on WebEx here. \n2024 IBC Use of Fire and Smoke Separations\n\nIdentify the general types of fire and smoke separations\nIdentify those specific components that make up fire and smoke separations\nDetermine where separations are required\nDetermine where separations are permitted as alternatives to other requirements\n\nFire and Smoke Protection Concepts\nTypes of Fire and Smoke Separations\nFire and Smoke Separation Components\nFire and Smoke Separation Locations\nBuilding Size\, Use and Components\nExitways\nFire Limitation Features\nSpecial Building Types\nSpecial Occupancies and Uses\nSpecial Building Features\nHazardous Uses\n\n\n\n2021 IBC Types of Construction Classification\n\nUse IBC Chapter 6 to determine the specific features of the twelve types of construction\n\nUnderstand the concept behind the use of construction type to regulate a building’s design and construction\nIdentify the characteristics of the 12 types of construction set forth in the 2024 IBC\nDetermine the details of construction type based on fire-resistance-rated protection\nIdentify those allowances where combustible materials are permitted in Type I and II buildings\n\n\n\nGroup Purchase Instructions\nIf you are buying multiple tickets for multiple people\, please purchase one ticket at a time so we can have each person’s name and email. Each time you purchase\, use the person you are buying for as the purchaser’s info on the checkout page. If you are buying for yourself\, check out using your name and email.
URL:https://metrokcicc.org/event/fire-and-smoke-separations-and-construction-classification/
LOCATION:Lenexa City Hall\, 17101 W 87th St Parkway\, Lenexa\, KS\, 66219\, United States
ATTACH;FMTTYPE=image/jpeg:https://metrokcicc.org/wp-content/uploads/sites/23/2025/11/Fire-and-Smoke-Separations-1.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/Chicago:20251211T090000
DTEND;TZID=America/Chicago:20251211T160000
DTSTAMP:20260414T043150
CREATED:20251120T164259Z
LAST-MODIFIED:20251121T174358Z
UID:424-1765443600-1765468800@metrokcicc.org
SUMMARY:Day 2 Training Allowable Heights and Areas + Mixed Occupancies
DESCRIPTION:Day 2 is organized by the Region IV. \nIn-Person or Virtual\nBoth days of training are offered either in person at Lenexa City Hall or virtually on WebEx here. \n2024 IBC Allowable Heights and Areas\n\nFamiliarize and assist code officials in locating\, describing and applying IBC requirements regarding mixed occupanciesDefine the concept for addressing mixed-occupancy buildings\n\nIdentify and apply the three options that are available for regulating mixed-occupancy buildings\nDescribe the relationship of occupancy classification\, allowable height\, allowable area and occupancy separation to mixed-occupancy buildings\nIdentify incidental uses and understand how they differ from mixed-occupancy conditions\n\n\nThis course provides an overview of the 2024 IBC Section 508 provisions for the application of code requirements addressing mixed occupancy buildings\nOther code provisions applicable to an understanding of mixed occupancies will also be addressed\n\n2024 IBC Mixed Occupancies\nThis seminar addresses the key issues of the 2024 International Building Code®️ (IBC®️) Chapter 5 regarding the determination of a building’s allowable height and area. The process for correctly evaluating a building for allowable height and area relies on a systematic approach\, including the determination of occupancy classification and construction type. \nUpon completion\, participants will be better able to \n\nDescribe the purpose for regulating a building’s allowable height and area\nIdentify the relationship of a building’s occupancy classification(s) and type of construction to a building’s allowable height and area\nDetermine how a building’s actual height\, both in stories above grade plane and feet\, and floor area are calculated\nDetermine how a building’s allowable height\, both in stories above grade plane and feet\, and floor area are determined\nApply the special provisions applicable to mixed occupancies\, unlimited area buildings and horizontal building separations\n\nGroup Purchase Instructions\nIf you are buying multiple tickets for multiple people\, please purchase one ticket at a time so we can have each person’s name and email. Each time you purchase\, use the person you are buying for as the purchaser’s info on the checkout page. If you are buying for yourself\, check out using your name and email.
URL:https://metrokcicc.org/event/allowable-heights-and-areas-mixed-occupancies/
LOCATION:Lenexa City Hall\, 17101 W 87th St Parkway\, Lenexa\, KS\, 66219\, United States
ATTACH;FMTTYPE=image/jpeg:https://metrokcicc.org/wp-content/uploads/sites/23/2025/11/mixed-occupancy-buildings-1.jpg
END:VEVENT
END:VCALENDAR